<?xml version="1.0" encoding="UTF-8"?>
<eudamedExport entity="devices">
  <row>
    <udiDi>06950900961762</udiDi>
    <basicUdiDi>69509009CEIKRW</basicUdiDi>
    <tradeName>06950900961762</tradeName>
    <deviceName>Introducer Set</deviceName>
    <manufacturerName>Shanghai INT Medical Instruments Co., Ltd.</manufacturerName>
    <manufacturerSrn>CN-MF-000009966</manufacturerSrn>
    <authorisedRepresentativeName>Shanghai International Holding Corp. GmbH(Europe)</authorisedRepresentativeName>
    <authorisedRepresentativeSrn>DE-AR-000000001</authorisedRepresentativeSrn>
    <riskClass>Sınıf IIa</riskClass>
    <legislation>MDR 2017/745</legislation>
    <emdnCode>C0504</emdnCode>
    <emdnDescription>ARTERIAL INTRODUCTION SETS</emdnDescription>
    <deviceStatus>Piyasada</deviceStatus>
    <reference>NIS05C</reference>
    <placedOnMarketCountry>Germany</placedOnMarketCountry>
    <lastUpdated>2026-06-28T06:18:32.154Z</lastUpdated>
  </row>
  <row>
    <udiDi>06950900961755</udiDi>
    <basicUdiDi>69509009CEIKRW</basicUdiDi>
    <tradeName>06950900961755</tradeName>
    <deviceName>Introducer Set</deviceName>
    <manufacturerName>Shanghai INT Medical Instruments Co., Ltd.</manufacturerName>
    <manufacturerSrn>CN-MF-000009966</manufacturerSrn>
    <authorisedRepresentativeName>Shanghai International Holding Corp. GmbH(Europe)</authorisedRepresentativeName>
    <authorisedRepresentativeSrn>DE-AR-000000001</authorisedRepresentativeSrn>
    <riskClass>Sınıf IIa</riskClass>
    <legislation>MDR 2017/745</legislation>
    <emdnCode>C0504</emdnCode>
    <emdnDescription>ARTERIAL INTRODUCTION SETS</emdnDescription>
    <deviceStatus>Piyasada</deviceStatus>
    <reference>IS05B</reference>
    <placedOnMarketCountry>Germany</placedOnMarketCountry>
    <lastUpdated>2026-06-28T06:18:24.858Z</lastUpdated>
  </row>
  <row>
    <udiDi>06950900961748</udiDi>
    <basicUdiDi>69509009CEIKRW</basicUdiDi>
    <tradeName>06950900961748</tradeName>
    <deviceName>Introducer Set</deviceName>
    <manufacturerName>Shanghai INT Medical Instruments Co., Ltd.</manufacturerName>
    <manufacturerSrn>CN-MF-000009966</manufacturerSrn>
    <authorisedRepresentativeName>Shanghai International Holding Corp. GmbH(Europe)</authorisedRepresentativeName>
    <authorisedRepresentativeSrn>DE-AR-000000001</authorisedRepresentativeSrn>
    <riskClass>Sınıf IIa</riskClass>
    <legislation>MDR 2017/745</legislation>
    <emdnCode>C0504</emdnCode>
    <emdnDescription>ARTERIAL INTRODUCTION SETS</emdnDescription>
    <deviceStatus>Piyasada</deviceStatus>
    <reference>MI5F01</reference>
    <placedOnMarketCountry>Germany</placedOnMarketCountry>
    <lastUpdated>2026-06-28T06:18:23.658Z</lastUpdated>
  </row>
  <row>
    <udiDi>06950900961670</udiDi>
    <basicUdiDi>69509009CEIKRW</basicUdiDi>
    <tradeName>06950900961670</tradeName>
    <deviceName>Introducer Set</deviceName>
    <manufacturerName>Shanghai INT Medical Instruments Co., Ltd.</manufacturerName>
    <manufacturerSrn>CN-MF-000009966</manufacturerSrn>
    <authorisedRepresentativeName>Shanghai International Holding Corp. GmbH(Europe)</authorisedRepresentativeName>
    <authorisedRepresentativeSrn>DE-AR-000000001</authorisedRepresentativeSrn>
    <riskClass>Sınıf IIa</riskClass>
    <legislation>MDR 2017/745</legislation>
    <emdnCode>C0504</emdnCode>
    <emdnDescription>ARTERIAL INTRODUCTION SETS</emdnDescription>
    <deviceStatus>Piyasada</deviceStatus>
    <reference>MI5F02</reference>
    <placedOnMarketCountry>Germany</placedOnMarketCountry>
    <lastUpdated>2026-06-28T06:18:22.468Z</lastUpdated>
  </row>
  <row>
    <udiDi>06950900961588</udiDi>
    <basicUdiDi>69509009CEIKRW</basicUdiDi>
    <tradeName>06950900961588</tradeName>
    <deviceName>Introducer Set</deviceName>
    <manufacturerName>Shanghai INT Medical Instruments Co., Ltd.</manufacturerName>
    <manufacturerSrn>CN-MF-000009966</manufacturerSrn>
    <authorisedRepresentativeName>Shanghai International Holding Corp. GmbH(Europe)</authorisedRepresentativeName>
    <authorisedRepresentativeSrn>DE-AR-000000001</authorisedRepresentativeSrn>
    <riskClass>Sınıf IIa</riskClass>
    <legislation>MDR 2017/745</legislation>
    <emdnCode>C0504</emdnCode>
    <emdnDescription>ARTERIAL INTRODUCTION SETS</emdnDescription>
    <deviceStatus>Piyasada</deviceStatus>
    <reference>CHTR04</reference>
    <placedOnMarketCountry>Germany</placedOnMarketCountry>
    <lastUpdated>2026-06-28T06:18:21.258Z</lastUpdated>
  </row>
  <row>
    <udiDi>06950900961090</udiDi>
    <basicUdiDi>69509009CEIKRW</basicUdiDi>
    <tradeName>06950900961090</tradeName>
    <deviceName>Introducer Set</deviceName>
    <manufacturerName>Shanghai INT Medical Instruments Co., Ltd.</manufacturerName>
    <manufacturerSrn>CN-MF-000009966</manufacturerSrn>
    <authorisedRepresentativeName>Shanghai International Holding Corp. GmbH(Europe)</authorisedRepresentativeName>
    <authorisedRepresentativeSrn>DE-AR-000000001</authorisedRepresentativeSrn>
    <riskClass>Sınıf IIa</riskClass>
    <legislation>MDR 2017/745</legislation>
    <emdnCode>C0504</emdnCode>
    <emdnDescription>ARTERIAL INTRODUCTION SETS</emdnDescription>
    <deviceStatus>Piyasada</deviceStatus>
    <reference>HNIS03A</reference>
    <placedOnMarketCountry>Germany</placedOnMarketCountry>
    <lastUpdated>2026-06-28T06:17:59.675Z</lastUpdated>
  </row>
  <row>
    <udiDi>06950900961083</udiDi>
    <basicUdiDi>69509009CEIKRW</basicUdiDi>
    <tradeName>06950900961083</tradeName>
    <deviceName>Introducer Set</deviceName>
    <manufacturerName>Shanghai INT Medical Instruments Co., Ltd.</manufacturerName>
    <manufacturerSrn>CN-MF-000009966</manufacturerSrn>
    <authorisedRepresentativeName>Shanghai International Holding Corp. GmbH(Europe)</authorisedRepresentativeName>
    <authorisedRepresentativeSrn>DE-AR-000000001</authorisedRepresentativeSrn>
    <riskClass>Sınıf IIa</riskClass>
    <legislation>MDR 2017/745</legislation>
    <emdnCode>C0504</emdnCode>
    <emdnDescription>ARTERIAL INTRODUCTION SETS</emdnDescription>
    <deviceStatus>Piyasada</deviceStatus>
    <reference>IS03C</reference>
    <placedOnMarketCountry>Germany</placedOnMarketCountry>
    <lastUpdated>2026-06-28T06:17:52.457Z</lastUpdated>
  </row>
  <row>
    <udiDi>06950900952586</udiDi>
    <basicUdiDi>69509009CEIKRW</basicUdiDi>
    <tradeName>06950900952586</tradeName>
    <deviceName>Introducer Set</deviceName>
    <manufacturerName>Shanghai INT Medical Instruments Co., Ltd.</manufacturerName>
    <manufacturerSrn>CN-MF-000009966</manufacturerSrn>
    <authorisedRepresentativeName>Shanghai International Holding Corp. GmbH(Europe)</authorisedRepresentativeName>
    <authorisedRepresentativeSrn>DE-AR-000000001</authorisedRepresentativeSrn>
    <riskClass>Sınıf IIa</riskClass>
    <legislation>MDR 2017/745</legislation>
    <emdnCode>C0504</emdnCode>
    <emdnDescription>ARTERIAL INTRODUCTION SETS</emdnDescription>
    <deviceStatus>Piyasada</deviceStatus>
    <reference>IS02A</reference>
    <placedOnMarketCountry>Germany</placedOnMarketCountry>
    <lastUpdated>2026-06-28T06:15:54.787Z</lastUpdated>
  </row>
  <row>
    <udiDi>06950900947735</udiDi>
    <basicUdiDi>69509009CEIKRW</basicUdiDi>
    <tradeName>06950900947735</tradeName>
    <deviceName>Introducer Set</deviceName>
    <manufacturerName>Shanghai INT Medical Instruments Co., Ltd.</manufacturerName>
    <manufacturerSrn>CN-MF-000009966</manufacturerSrn>
    <authorisedRepresentativeName>Shanghai International Holding Corp. GmbH(Europe)</authorisedRepresentativeName>
    <authorisedRepresentativeSrn>DE-AR-000000001</authorisedRepresentativeSrn>
    <riskClass>Sınıf IIa</riskClass>
    <legislation>MDR 2017/745</legislation>
    <emdnCode>C0504</emdnCode>
    <emdnDescription>ARTERIAL INTRODUCTION SETS</emdnDescription>
    <deviceStatus>Piyasada</deviceStatus>
    <reference>TR00</reference>
    <placedOnMarketCountry>Germany</placedOnMarketCountry>
    <lastUpdated>2026-06-28T06:15:46.378Z</lastUpdated>
  </row>
  <row>
    <udiDi>06950900941337</udiDi>
    <basicUdiDi>69509009CEIKRW</basicUdiDi>
    <tradeName>06950900941337</tradeName>
    <deviceName>Introducer Set</deviceName>
    <manufacturerName>Shanghai INT Medical Instruments Co., Ltd.</manufacturerName>
    <manufacturerSrn>CN-MF-000009966</manufacturerSrn>
    <authorisedRepresentativeName>Shanghai International Holding Corp. GmbH(Europe)</authorisedRepresentativeName>
    <authorisedRepresentativeSrn>DE-AR-000000001</authorisedRepresentativeSrn>
    <riskClass>Sınıf IIa</riskClass>
    <legislation>MDR 2017/745</legislation>
    <emdnCode>C0504</emdnCode>
    <emdnDescription>ARTERIAL INTRODUCTION SETS</emdnDescription>
    <deviceStatus>Piyasada</deviceStatus>
    <reference>TR01A</reference>
    <placedOnMarketCountry>Germany</placedOnMarketCountry>
    <lastUpdated>2026-06-28T06:14:27.130Z</lastUpdated>
  </row>
  <row>
    <udiDi>06950900941313</udiDi>
    <basicUdiDi>69509009CEIKRW</basicUdiDi>
    <tradeName>06950900941313</tradeName>
    <deviceName>Introducer Set</deviceName>
    <manufacturerName>Shanghai INT Medical Instruments Co., Ltd.</manufacturerName>
    <manufacturerSrn>CN-MF-000009966</manufacturerSrn>
    <authorisedRepresentativeName>Shanghai International Holding Corp. GmbH(Europe)</authorisedRepresentativeName>
    <authorisedRepresentativeSrn>DE-AR-000000001</authorisedRepresentativeSrn>
    <riskClass>Sınıf IIa</riskClass>
    <legislation>MDR 2017/745</legislation>
    <emdnCode>C0504</emdnCode>
    <emdnDescription>ARTERIAL INTRODUCTION SETS</emdnDescription>
    <deviceStatus>Piyasada</deviceStatus>
    <reference>TR02AR</reference>
    <placedOnMarketCountry>Germany</placedOnMarketCountry>
    <lastUpdated>2026-06-28T06:14:19.915Z</lastUpdated>
  </row>
  <row>
    <udiDi>06950900941146</udiDi>
    <basicUdiDi>69509009CEIKRW</basicUdiDi>
    <tradeName>06950900941146</tradeName>
    <deviceName>Introducer Set</deviceName>
    <manufacturerName>Shanghai INT Medical Instruments Co., Ltd.</manufacturerName>
    <manufacturerSrn>CN-MF-000009966</manufacturerSrn>
    <authorisedRepresentativeName>Shanghai International Holding Corp. GmbH(Europe)</authorisedRepresentativeName>
    <authorisedRepresentativeSrn>DE-AR-000000001</authorisedRepresentativeSrn>
    <riskClass>Sınıf IIa</riskClass>
    <legislation>MDR 2017/745</legislation>
    <emdnCode>C0504</emdnCode>
    <emdnDescription>ARTERIAL INTRODUCTION SETS</emdnDescription>
    <deviceStatus>Piyasada</deviceStatus>
    <reference>CHTR04CR</reference>
    <placedOnMarketCountry>Germany</placedOnMarketCountry>
    <lastUpdated>2026-06-28T06:13:40.294Z</lastUpdated>
  </row>
  <row>
    <udiDi>06950900941139</udiDi>
    <basicUdiDi>69509009CEIKRW</basicUdiDi>
    <tradeName>06950900941139</tradeName>
    <deviceName>Introducer Set</deviceName>
    <manufacturerName>Shanghai INT Medical Instruments Co., Ltd.</manufacturerName>
    <manufacturerSrn>CN-MF-000009966</manufacturerSrn>
    <authorisedRepresentativeName>Shanghai International Holding Corp. GmbH(Europe)</authorisedRepresentativeName>
    <authorisedRepresentativeSrn>DE-AR-000000001</authorisedRepresentativeSrn>
    <riskClass>Sınıf IIa</riskClass>
    <legislation>MDR 2017/745</legislation>
    <emdnCode>C0504</emdnCode>
    <emdnDescription>ARTERIAL INTRODUCTION SETS</emdnDescription>
    <deviceStatus>Piyasada</deviceStatus>
    <reference>CHTR04C</reference>
    <placedOnMarketCountry>Germany</placedOnMarketCountry>
    <lastUpdated>2026-06-28T06:13:39.080Z</lastUpdated>
  </row>
  <row>
    <udiDi>06950900941122</udiDi>
    <basicUdiDi>69509009CEIKRW</basicUdiDi>
    <tradeName>06950900941122</tradeName>
    <deviceName>Introducer Set</deviceName>
    <manufacturerName>Shanghai INT Medical Instruments Co., Ltd.</manufacturerName>
    <manufacturerSrn>CN-MF-000009966</manufacturerSrn>
    <authorisedRepresentativeName>Shanghai International Holding Corp. GmbH(Europe)</authorisedRepresentativeName>
    <authorisedRepresentativeSrn>DE-AR-000000001</authorisedRepresentativeSrn>
    <riskClass>Sınıf IIa</riskClass>
    <legislation>MDR 2017/745</legislation>
    <emdnCode>C0504</emdnCode>
    <emdnDescription>ARTERIAL INTRODUCTION SETS</emdnDescription>
    <deviceStatus>Piyasada</deviceStatus>
    <reference>CHTR04AR</reference>
    <placedOnMarketCountry>Germany</placedOnMarketCountry>
    <lastUpdated>2026-06-28T06:13:37.878Z</lastUpdated>
  </row>
  <row>
    <udiDi>06950900941115</udiDi>
    <basicUdiDi>69509009CEIKRW</basicUdiDi>
    <tradeName>06950900941115</tradeName>
    <deviceName>Introducer Set</deviceName>
    <manufacturerName>Shanghai INT Medical Instruments Co., Ltd.</manufacturerName>
    <manufacturerSrn>CN-MF-000009966</manufacturerSrn>
    <authorisedRepresentativeName>Shanghai International Holding Corp. GmbH(Europe)</authorisedRepresentativeName>
    <authorisedRepresentativeSrn>DE-AR-000000001</authorisedRepresentativeSrn>
    <riskClass>Sınıf IIa</riskClass>
    <legislation>MDR 2017/745</legislation>
    <emdnCode>C0504</emdnCode>
    <emdnDescription>ARTERIAL INTRODUCTION SETS</emdnDescription>
    <deviceStatus>Piyasada</deviceStatus>
    <reference>CHTR04R</reference>
    <placedOnMarketCountry>Germany</placedOnMarketCountry>
    <lastUpdated>2026-06-28T06:13:31.877Z</lastUpdated>
  </row>
  <row>
    <udiDi>06950900941108</udiDi>
    <basicUdiDi>69509009CEIKRW</basicUdiDi>
    <tradeName>06950900941108</tradeName>
    <deviceName>Introducer Set</deviceName>
    <manufacturerName>Shanghai INT Medical Instruments Co., Ltd.</manufacturerName>
    <manufacturerSrn>CN-MF-000009966</manufacturerSrn>
    <authorisedRepresentativeName>Shanghai International Holding Corp. GmbH(Europe)</authorisedRepresentativeName>
    <authorisedRepresentativeSrn>DE-AR-000000001</authorisedRepresentativeSrn>
    <riskClass>Sınıf IIa</riskClass>
    <legislation>MDR 2017/745</legislation>
    <emdnCode>C0504</emdnCode>
    <emdnDescription>ARTERIAL INTRODUCTION SETS</emdnDescription>
    <deviceStatus>Piyasada</deviceStatus>
    <reference>CHTR03CR</reference>
    <placedOnMarketCountry>Germany</placedOnMarketCountry>
    <lastUpdated>2026-06-28T06:13:30.678Z</lastUpdated>
  </row>
  <row>
    <udiDi>06950900941092</udiDi>
    <basicUdiDi>69509009CEIKRW</basicUdiDi>
    <tradeName>06950900941092</tradeName>
    <deviceName>Introducer Set</deviceName>
    <manufacturerName>Shanghai INT Medical Instruments Co., Ltd.</manufacturerName>
    <manufacturerSrn>CN-MF-000009966</manufacturerSrn>
    <authorisedRepresentativeName>Shanghai International Holding Corp. GmbH(Europe)</authorisedRepresentativeName>
    <authorisedRepresentativeSrn>DE-AR-000000001</authorisedRepresentativeSrn>
    <riskClass>Sınıf IIa</riskClass>
    <legislation>MDR 2017/745</legislation>
    <emdnCode>C0504</emdnCode>
    <emdnDescription>ARTERIAL INTRODUCTION SETS</emdnDescription>
    <deviceStatus>Piyasada</deviceStatus>
    <reference>CHTR03C</reference>
    <placedOnMarketCountry>Germany</placedOnMarketCountry>
    <lastUpdated>2026-06-28T06:13:29.482Z</lastUpdated>
  </row>
  <row>
    <udiDi>06950900941085</udiDi>
    <basicUdiDi>69509009CEIKRW</basicUdiDi>
    <tradeName>06950900941085</tradeName>
    <deviceName>Introducer Set</deviceName>
    <manufacturerName>Shanghai INT Medical Instruments Co., Ltd.</manufacturerName>
    <manufacturerSrn>CN-MF-000009966</manufacturerSrn>
    <authorisedRepresentativeName>Shanghai International Holding Corp. GmbH(Europe)</authorisedRepresentativeName>
    <authorisedRepresentativeSrn>DE-AR-000000001</authorisedRepresentativeSrn>
    <riskClass>Sınıf IIa</riskClass>
    <legislation>MDR 2017/745</legislation>
    <emdnCode>C0504</emdnCode>
    <emdnDescription>ARTERIAL INTRODUCTION SETS</emdnDescription>
    <deviceStatus>Piyasada</deviceStatus>
    <reference>CHTR03AR</reference>
    <placedOnMarketCountry>Germany</placedOnMarketCountry>
    <lastUpdated>2026-06-28T06:13:28.277Z</lastUpdated>
  </row>
  <row>
    <udiDi>06950900941078</udiDi>
    <basicUdiDi>69509009CEIKRW</basicUdiDi>
    <tradeName>06950900941078</tradeName>
    <deviceName>Introducer Set</deviceName>
    <manufacturerName>Shanghai INT Medical Instruments Co., Ltd.</manufacturerName>
    <manufacturerSrn>CN-MF-000009966</manufacturerSrn>
    <authorisedRepresentativeName>Shanghai International Holding Corp. GmbH(Europe)</authorisedRepresentativeName>
    <authorisedRepresentativeSrn>DE-AR-000000001</authorisedRepresentativeSrn>
    <riskClass>Sınıf IIa</riskClass>
    <legislation>MDR 2017/745</legislation>
    <emdnCode>C0504</emdnCode>
    <emdnDescription>ARTERIAL INTRODUCTION SETS</emdnDescription>
    <deviceStatus>Piyasada</deviceStatus>
    <reference>CHTR03R</reference>
    <placedOnMarketCountry>Germany</placedOnMarketCountry>
    <lastUpdated>2026-06-28T06:13:22.273Z</lastUpdated>
  </row>
  <row>
    <udiDi>06950900941061</udiDi>
    <basicUdiDi>69509009CEIKRW</basicUdiDi>
    <tradeName>06950900941061</tradeName>
    <deviceName>Introducer Set</deviceName>
    <manufacturerName>Shanghai INT Medical Instruments Co., Ltd.</manufacturerName>
    <manufacturerSrn>CN-MF-000009966</manufacturerSrn>
    <authorisedRepresentativeName>Shanghai International Holding Corp. GmbH(Europe)</authorisedRepresentativeName>
    <authorisedRepresentativeSrn>DE-AR-000000001</authorisedRepresentativeSrn>
    <riskClass>Sınıf IIa</riskClass>
    <legislation>MDR 2017/745</legislation>
    <emdnCode>C0504</emdnCode>
    <emdnDescription>ARTERIAL INTRODUCTION SETS</emdnDescription>
    <deviceStatus>Piyasada</deviceStatus>
    <reference>CTR04CR</reference>
    <placedOnMarketCountry>Germany</placedOnMarketCountry>
    <lastUpdated>2026-06-28T06:13:21.074Z</lastUpdated>
  </row>
</eudamedExport>